Meet the 90kVA Cummins generator. The C90D5 moves up to Cummins’ six-cylinder 6BTA5.9 engine, one of the best-known industrial engines in Africa. It has an electronic governor for tight speed control, a Stamford UCI224G alternator and the PowerCommand 1.2 control panel. With a 350-litre base tank, it’s built to run for a long time.
It suits hospitals, hotels, office blocks, cold-storage and food businesses, and factories with a three-phase supply.
What it will run
It delivers 66kW prime and 72kW standby, about 22kW per phase at prime rating. That covers a hotel, a medium hospital wing, a cold-storage facility, or a factory with several production lines.
Why the electronic governor matters
An electronic governor holds the engine speed, and therefore the frequency, very steady as loads switch on and off. That protects sensitive equipment like medical devices, servers and variable-speed drives.
Fuel and running time
It uses 21.2 litres an hour at full load, so the 350-litre base tank lasts about 16 hours flat out and far longer at a normal load.
Specifications
| Model | Cummins C90D5 |
| Standby power | 90kVA / 72kW |
| Prime power | 82kVA / 66kW |
| Phase | Three phase, 380 to 415V, 50Hz |
| Current | 129.6A per phase |
| Engine | Cummins 6BTA5.9-G5, 6 cylinder, electronic governor, 1500rpm |
| Alternator | Stamford UCI224G |
| Control panel | Cummins PowerCommand 1.2 |
| Breaker | 4-pole circuit breaker |
| Base fuel tank | 350 litres |
| Fuel use | 21.2 litres per hour at 100% load |
| Noise level | 78dB(A) at 1m |
| Weight | 1,944kg (dry) |
| Dimensions (L x W x H) | 3151 x 1142 x 1714mm |
| Warranty | 1 year / 500 hours standby, or 1 year unlimited hours prime |
Installation
Generators in this class need a proper plan: a level concrete plinth, room for airflow and service access, a correctly sized cable run to the main board, and an automatic transfer switch rated for your supply. The installation must be done by a registered electrician, who issues a Certificate of Compliance. We handle delivery, crane offloading, installation and commissioning. See our installation guide for more.
Part of our Cummins range: see all Cummins generators for sale, from 17kVA to 450kVA.
Comparing options around this size? See 85kVA vs 88kVA vs 90kVA: Hyundai, Cat or Cummins.
Common questions
How long does the tank last?
About 16 hours at full load and well over a day at a typical working load.
What comes next in the range?
The 110kVA Cummins uses the same engine with a bigger alternator and tank.